Cement hydration in concrete is an exothermic reaction and as a result concrete temperature can rise significantly in the early age maturing if the heat is not dissipated into the environment. Such rise in temperatures has many adverse consequences especially for the thick elements, with steam curing or high level of insulation.  . 
If the temperature is higher than a certain limit (e.g. 70 °C for GP cement and 80 °C for blend cements) the a unstable cement hydration product (monosulphoaluminate phase called AFm) can form and it will transfer into ettringite (AFt) phase with significant volume increase.  Such an expansion process will disintegrate the concrete matrix causing premature distress. 
In addition, the strength of concrete in early age experiencing high temperature will form  coarse crystal grains with  significantly lower strength compared to those cured in normal temperatures.  It is critical to control concrete peak temperature below the limits so that the durability is not compromised.  The best practice is to conduct thermal modelling using CIRIA C660 or C766 to predict temperature rise considering the specific structure dimension, configurations, reinforcement details, concrete mix characteristic, formwork type, retention time and ambient conditions. 
In addition, the high early age temperature in concrete under external restraint can also expand while concrete has a good plasticity.  After peak temperature, the temperature of concrete decreases gradually when contraction occurs. However, the contraction of such a hardened concrete may be restrained by the joining elements (such footing or base slab) constructed early.  Tensile strength will develop and if the stress is greater than the concrete tensile strength, which is very low at early age, cracking will occur through the entire depth of the elements.
Such cracks are permanent and may grow in width with increasing drying shrinkage.  It is important to control such cracks as the durability will be compromised with such cracks especially in aggressive conditions.  The thermal modelling can be used to estimate external restraint and assess the cracking risk so that preventive measures can be selected and adopted.       
Another consequence of high peak temperature in concrete with insufficient insulation/formwork is a high temperature differential between surface and centre of concrete elements.  Concrete has a relatively low thermal conductivity and heat transfer is slow within elements.  Cooling is fast on surfaces with a lower temperature than the centre and the contraction of surface concrete is restrained by the centre hot concrete, tensile stress thus develops.  The stress level increase with temperature differential and at a certain differential, stress exceeds tensile strength and cracking occurs.  The maximum allowable differential to avoid cracking decreases with coefficient thermal expansion of concrete related to aggregate type.
To avoid cracking risk under internal restraint, BAE’s engineers have the leading expertise in such thermal modelling work and have successfully delivered numerous thermal reports in Australia and abroad. In addition, more advanced models than the original CIRIA C660 model have been developed by BAE’s engineers to predict temperatures in concrete with cooling pipe systems and in cylinder elements with radial heat transfer  to ground. 
Furthermore, the model to estimate the edge restraint of pile-caps or headstock by spaced piles or pier columns are also developed and used in many projects.  We have also developed unique solutions to reduce the external restraint level by construction sequential. We have also adopted a sophisticated method to estimate heat of cement hydration curve by analysing the results from hot box testing of concrete blocks.   
The early age thermal modelling techniques can be also used to determine the causes of cracking in various concrete elements.  BAE’s engineers have rich experience in cracking investigations on causes of cracking in some concrete elements such as concrete water tanks, pavement slabs, bridge decks, toppings and warehouse slabs.   
We  monitored the temperature history in various concrete and metal elements such as large thick raft slab, large pile-caps, hot box concrete blocks, and building slabs etc. We have used datalogging system in most the cases to obtain accurate and continuous data in-situ or remotely.  The results can be used to determine the current performances of the elements and whether there is any abnormal behaviour. 
The results of hot box testing can be used to determine the adiabatic temperature rise curve in concrete.  It is the critical information for concrete early age thermal modelling and cracking analysis and control/prevention.